EN 61000-6-1 EMC Standards for Residential and Commercial Environments
European standard specifying electromagnetic compatibility immunity requirements for electrical and electronic equipment intended for use in residential, commercial, and light-industrial environments, including motorcycle key programming and diagnostic equipment.
Standard Overview
Publication Date
2019 (Latest Edition)
Status
European Standard (EN)
Application
EMC Immunity Standards
Environment
Residential & Commercial
Immunity Requirements
Electrostatic Discharge (ESD)
IEC 61000-4-2
Protection against electrostatic discharge events
- Contact discharge: ±4 kV
- Air discharge: ±8 kV
- Performance criterion B
Radiated RF Immunity
IEC 61000-4-3
Immunity to radiated electromagnetic fields
- Frequency: 80 MHz - 1 GHz
- Field strength: 3 V/m
- 80% AM modulation at 1 kHz
Electrical Fast Transients
IEC 61000-4-4
Immunity to electrical fast transient/burst
- AC power ports: ±1 kV
- Signal/control ports: ±0.5 kV
- Repetition frequency: 5 kHz
Surge Immunity
IEC 61000-4-5
Immunity to surge voltages
- Line-to-line: ±1 kV
- Line-to-earth: ±2 kV
- 1.2/50 μs voltage wave
Conducted RF Immunity
IEC 61000-4-6
Immunity to conducted RF disturbances
- Frequency: 150 kHz - 80 MHz
- Test level: 3 V (rms)
- 80% AM modulation at 1 kHz
Voltage Dips and Interruptions
IEC 61000-4-11
Immunity to voltage dips and short interruptions
- Voltage dips: 70% for 25 periods
- Short interruptions: 5% for 250 periods
- Performance criterion C
Implementation Features
Test Setup Requirements
Essential test equipment and setup requirements for EN 61000-6-1 immunity testing.
- ESD generators with specified discharge networks
- RF signal generators with modulation capability
- Power amplifiers for field generation
- Anechoic chambers for radiated immunity testing
- Coupling/decoupling networks for conducted tests
- Voltage variation and interruption simulators
Performance Criteria
Classification system for equipment performance during immunity testing.
- Criterion A: Normal performance within specification limits
- Criterion B: Temporary degradation, self-recoverable
- Criterion C: Temporary loss of function, operator intervention required
- Performance monitoring during test exposure
- Post-test functionality verification
- Documentation of any performance degradation
Design Guidelines
Best practices for designing equipment to meet EN 61000-6-1 immunity requirements.
- Robust power supply design with filtering
- Proper grounding and shielding implementation
- ESD protection circuits and components
- Surge protection devices and circuits
- RF immunity through filtering and layout
- Voltage tolerance and backup power systems